ULTRAVIOLET WATER DISINFECTION

pmtoc-Aqualight

series
Model PMTOC-1 to PMTOC-10

Flow rate 1gpm up to 10gpm, The TOC
reduction systems are designed
specifically for the reduction of total
organic carbon level

These systems are designed with shorter wavelength UV
lamps emitting their spectral output at 185nm. These
"shorter" wavelength lamps emit more energy than standard
254nm lamps producing hydroxyl free radicals (OH) which is
turn oxidizes most organics into carbon dioxide (CO2) and
water (H2O). All TOC reduction systems produce UV dosages
in excess 120mJ/cm2 at the end of lamp life

pmtoc - Aqualight
pmtoc - Aqualight
ModelPMTOC-1PMTOC-3PMTOC-6PMTOC-8PMTOC-10
Flow Rates @ 120mJ/cm²1gpm, 3.8lpm, 0.25m³/hr3gpm, 11.5lpm, 0.7m³/hr6gpm, 23lpm, 1.4m³/hr8gpm, 30lpm, 1.8m³/hr10gpm, 38lpm, 2.3m³/hr
Inlet/Outlet½”½”¾”¾”¾”

Dimensions

43*6.5cm
                           (17*2.5 in.)
95*6.5cm
                           (37.4*2.5 in.)
60*8.9cm
                           (23.6*3.5 in.)
79*8.9cm
                           (31.1*3.5 in.)
95*8.9cm
                           (37.4*3.5 in.)
Ultraviolet LmapGPH330T5VH-LT, 28
                           Watts, 425mA, 185nm
G36T5VH-LT, 39 Watts,
                           425mA, 185nm
GHO512T5VH-LT, 50
                           Watts, 800mA, 185nm
GHO702T5VH-LT, 65
                           Watts, 800mA, 185nm
GHO36T5VH-LT, 80 Watts,
                           800mA, 185nm
Quartz SleeveQS375QS890QS542QS732QS890
Advanced ControllerPart No. BAP40365, Universal Voltage100V.-250V./50-60Hz., 18*9.5*5cm (7.1*3.7*2 in.)
Part No. BAP100365, Universal Voltage100V.-250V./50-60Hz.,18*9.5*5cm (7.1*3.7*2 in.)
FeaturesLamp Operating Indicator, Audible Lamp Failure, Lamp Life 365 Days Countdown, Total Running Days, Dry Contact
▶ Flow Rates Stated at 95% UV Transmittance of End of Lamp Life, 20ºC